A/RH3-AN-O
Humidity Sensor, 0% to 100%RH, 3% Accuracy, 4mA to 20mA O/P, Outside Air Euro Enclosure, 10 kohm

| Manufacturer | ACI |
|---|---|
| Manufacturer Part No | A/RH3-AN-OCopy |
| Newark Part No. | 10AN8360 |
| Your Part Number | |
| Technical Datasheet |
| Quantity | Price |
|---|---|
| 1+ | $498.180 |
Product Information
| Manufacturer | ACI |
|---|---|
| Manufacturer Part No | A/RH3-AN-OCopy |
| Newark Part No. | 10AN8360 |
| Technical Datasheet | |
| Sensor Output Type | 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC - Field Selectable |
| Humidity Range | 0% to 100% Relative Humidity |
| Supply Voltage Min | 15VDC |
| Supply Voltage Max | 40VDC |
| Sensing Accuracy | 3% |
| Sensor Mounting | Duct Mount |
| Operating Temperature Min | -40°C |
| Operating Temperature Max | 60°C |
| Product Range | - |
| Qualification | - |
| SVHC | To Be Advised |
Product Overview
A/RH3-AN-O is a RHx-AN series relative humidity, outside air thermistor. It utilizes a thermoset polymer capacitive sensing element with a factory-applied hygroscopic filter to deliver a proportional analogue current or voltage output signal. The hygroscopic filter provides added resistance to moisture, dust, and other chemicals for greater long-term reliability. The RH outside air transmitter features integral DIP switches for field selection of the proper output signal and supply voltage to meet the user's application requirements. Field calibration can also be performed by using the increment and decrement calibration DIP switches without the need to replace the sensing element. These enhancements provide increased flexibility and outstanding long-term reliability. Applications include monitoring outdoor air humidity, economizer control, psychrometric calculations such as enthalpy and dew point, and wash-down applications.
- 10kohm nominal thermistor resistive output at 77°F (25°C)
- White/white lead wire colors
- Outside air (Euro enclosure) configuration
- RH measurement range from 0-100%
- Operating RH range from 0 to 95% RH, non-condensing (conformally coated PCB’s)
- Operating temperature range from -40 to 140°F (-40 to 60°C)
- RH response time (T63) is 20seconds typical
- Capacitive with hydrophobic filter RH sensor type
- RH transmitter stabilization time is 30minutes (recommended time before doing accuracy verification)
- RH terminal block torque rating range from 4.43 to 5.31lb-in (0.5 to 0.6Nm)
Technical Specifications
| Sensor Output Type | 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC - Field Selectable |
|---|---|
| Supply Voltage Min | 15VDC |
| Sensing Accuracy | 3% |
| Operating Temperature Min | -40°C |
| Product Range | - |
| SVHC | To Be Advised |
| Humidity Range | 0% to 100% Relative Humidity |
|---|---|
| Supply Voltage Max | 40VDC |
| Sensor Mounting | Duct Mount |
| Operating Temperature Max | 60°C |
| Qualification | - |
Technical Docs (1)
Legislation and Environmental
| US ECCN: | EAR99 |
|---|---|
| EU ECCN: | Unknown |
| RoHS Compliant: | Yes RoHS |
| RoHS Phthalates Compliant: | Yes RoHS |
| SVHC: | To Be Advised |
| Download Product Compliance Certificate | Product Compliance Certificate |